dzięki za zainteresowanie tematem

[ Dodano: 2017-03-16, 12:24 ]
No niestety, chyba nic z tego nie będzie, kupiłem kabel 8x0.75 ekranowany splotem, żadnej różnicy, nic, zero, null, cały czas tak samo, może jakiś kabel z wtyczką, która też jest mocno ekranowana, muszę poszukać....
[ Dodano: 2017-03-16, 12:49 ]
No ale odpisali mi z cncdrive:
"The Arm1 and Arm2 polarity connection when you see the vertical line and a servo limit override error on the drive is the wrong polarity connection, you have to connect it up in reverse and that is the correct connection polarity.
I understand that it is oscillationg, but that is the correct polarity and you have to tune the PID controller for your motor and system.
Also make sure to not comand a longer movement distance than the max.error parameter, because if you do then it will immediately cause a servo limit override error, because the servo position error will initially become larger than the allowed max. error limit you setup, so the drive will then go to a limit override fault."
Tylko nie rozumiem za bardzo od strony technicznej drugiej części odpowiedzi (od Also make...)
[ Dodano: 2017-03-16, 13:26 ]
DZIAŁA!!!!!!!! Zostałem wprowadzony w błąd na samym początku, gdy pytałem się o podłączenie silnika,
pytałem bo przeraziłem się, że silnik oscyluje i hałasuje i że zaraz coś się z nim stanie, powiedziano mi, że powinien być podpięty odwrotnie i mam sprawdzać nie na oscylacji silnika, odpowiedź z Cncdrive wyjaśniła wszystko

Dzięki 251mz, miałeś rację, że to kwestia ustawień