12550 Channel %1 block %2 identifier %3 not defined or option does not exist
%1 = Channel number
%2 = Block number, label
%3 = Source symbol
The displayed identifier was not defined before being used.
Macro: Keyword, to be defined with the DEFINE ... AS ... instruction is missing in one of the files:
_N_SMAC_DEF, _N_MMAC_DEF, _N_UMAC_DEF, _N_SGUD_DEF, _N_MGUD_DEF, _N_UGUD_DEF
Variable: DEF instruction missing
Program: PROC declaration missing
Alarm display. Interface signals are set. Correction block.
Press the NC Stop key and select the function „Correction block“ with the softkey PROGRAM CORRECT. The
correction pointer positions on the incorrect block.
- Correct the names used (typing error)
- Check the definition of variables, subroutines and macros
Może zmienna _KT[0,0] jest nie zadeklarowana. N15_KT[0,0]=REP(0) między N15 a podkreśleniem (_KT) jest spacja ?
[ Dodano: 2010-03-05, 15:57 ]
W katalogu "Definicje" powinien być plik :
%_N_GUD7_DEF
;$PATH=/_N_DEF_DIR
;V04.03.02 18.12.97 Sca Datenbaustein fr Zyklen
APR 11 APW 11
N10 DEF CHAN REAL _KT[92,11]
N20 DEF CHAN INT _ZSD[4]=0
N99 M02